CHART 1 | SURVEY OF ACCESSIBILITY TO PUBLIC BUILDINGS
|
![](imagenes/pix_blanc.gif) |
|
REFERENCE |
I agree: 3
points |
I partially agree: 2
points |
I disagree: 1
point |
|
|
|
|
![](imagenes/pix_blanc.gif) |
|
![](imagenes/05env_pix.gif) |
1| MAIN ENTRANCE AND EMERGENCY
DOORS |
|
|
|
1 | The entrance is
level or ramped, with no steps at the threshold. |
|
2 | A ramp is not necessary
to access this building, or there is one, which is correct, with
handrails at both sides and no more than 12% of gradient. |
|
3 | The only main entrance
has no turnstiles or revolving doors. |
|
4 | The floor outside
and inside the main door is hard, level and non-skid. It is dry
and clean. |
|
5 | The doorway is wide
enough for a wheelchair to enter (minimum width: 0.80m), with a
free "circle" of 1.50m diameter at either side of the main door. |
|
6 | The door opens automatically
or has a door knob easy to manipulate, or the door is not automatic
but it is not heavy to push or pull. |
|
7 | The emergency door
is very accessible from the entire building. The doorway, the door,
the floor and the exit are very accessible for a wheelchair user.
The way to the emergency door is also clearly indicated inside the
building. |
|
|
|
![](imagenes/05env_pix.gif) |
2 | ALARMS |
|
|
|
8 | The height of the
alarm controls is between 1.00m and 1.40m. |
|
9 | The alarms and
warnings have audible and clearly visible signals as well as flashing
lights. |
|
|
|
![](imagenes/05env_pix.gif) |
3 | FIRE EXTINGUISHERS |
|
|
|
10 | Fire extinguishers
are accessible for an ambulant disabled as well as for a wheelchair
user, as they are placed at a height of between 0.60m and 1.40m. |
|
|
|
![](imagenes/05env_pix.gif) |
4 | PUBLIC TELEPHONES |
|
|
|
11 | There is at least
one adapted public telephone in an accessible area of the building. |
|
12 | The telephone
is between 1.00m and 1.40m high and it has a free space of 0.70m
below for the wheelchair to approach. |
|
|
|
![](imagenes/05env_pix.gif) |
5 | SIGNS AND SIGNALS |
|
|
|
13 | Directions and
warnings are clear, easy to read and visible. They are placed at
a height of 1.00m and 1.70m. |
|
14 | There are adapted
signals for the blind at least outside and inside lift cabins and
on the toilet doors. |
|
|
|
![](imagenes/05env_pix.gif) |
6 | CORRIDORS |
|
|
|
15 | Corridors have
a minimum width of 1.50m. |
|
16 | They are free
of obstacles and the floor is hard, level and non-skid. |
|
|
|
![](imagenes/05env_pix.gif) |
7 | LIFTS |
|
|
|
17 | There is at least
one lift that gives access to the entire building. |
|
18 | The gap between
the floor and the lift cabin is no more than 0.01m wide. |
|
19 | There is a free
doorway at least 0.80m wide. |
|
20 | The interior minimum
dimensions of the lift are 1.40m x 1.10m. |
|
21 | Controls are between
1.00m and 1.40m from the floor. |
|
22 | There are grab
bars at 0.90m/0.95m from the floor on both sides of the cabin. |
|
|
|
![](imagenes/05env_pix.gif) |
8 | STAIRS |
|
|
|
23 | There are double
handrails on both sides. |
|
24 | The handrails
are placed between 0.90m/0.95m from the floor. The handrails are
firmly attached so that they do not move or look insecure. |
|
25 | The handrails
are round or oval and separated at least 0.04m from the wall or
other elements. |
|
26 | The surface of
the steps is hard, level and non-skid. |
|
27 | There are no protruding
nosing steps. |
|
28 | There are no open
steps. |
|
29 | The maximum height
of every step is 0.16m and the minimum length of every step is 0.30m. |
|
|
|
![](imagenes/05env_pix.gif) |
9 | TOILETS |
|
|
|
30 | The door of the
toilet opens outwards. |
|
31 | There is a free
circular space of 1.50m diameter in the interior. |
|
32 | There are adjustable
grab bars at both sides of WC. |
|
33 | The WC seat is
adjustable or has a seat extender. |
|
34 | The bottom of
the mirror is no higher than 0.90m. |
|
35 | The lower part
of the basin is free of obstacles and placed no less than 0.70m
from the floor. |
|
36 | All elements,
controls and mechanisms are placed between 1.60 m and 1.40m from
the floor. |
|
|
|
![](imagenes/05env_pix.gif) |
10 | ACCESSIBILITY TO THE
ENTIRE BUILDING |
|
|
|
37 | It is possible
to access the entire building without need of asking for help. |
|
38 | There are no isolated
steps or other elements that may obstacle the passage of a wheelchair
or a blind person. |
|
39 | The building is
well illuminated. |
|
40 | There are adapted
toilets on every floor of the building and they are always unlocked. |
|
|
|
|
Between 90
and 120: ACCESSIBLE |
. |
Between 60
and 89: ACCESSIBLE WITH DIFFICULTY
|
. |
Less than 59:
NOT ACCESSIBLE |
. |
|
|
|
|
|
|
|
|