         CHART 1 | SURVEY OF ACCESSIBILITY TO PUBLIC BUILDINGS 
          
       | 
    
     
        | 
        | 
       
        
           
            | REFERENCE | 
            I agree: 3 
              points | 
           
           
            | I partially agree: 2 
              points  | 
           
           
            | I disagree: 1 
              point | 
           
         
       | 
    
     
      |   | 
        | 
        | 
        | 
    
     
      |   | 
        | 
      1| MAIN ENTRANCE AND EMERGENCY 
        DOORS  | 
        | 
    
     
      |   | 
        | 
       
        
           
            | 1 | The entrance is 
              level or ramped, with no steps at the threshold.  | 
             
              
             | 
           
           
            | 2 | A ramp is not necessary 
              to access this building, or there is one, which is correct, with 
              handrails at both sides and no more than 12% of gradient. | 
             
              
             | 
           
           
            | 3 | The only main entrance 
              has no turnstiles or revolving doors. | 
             
              
             | 
           
           
            | 4 | The floor outside 
              and inside the main door is hard, level and non-skid. It is dry 
              and clean. | 
             
              
             | 
           
           
            | 5 | The doorway is wide 
              enough for a wheelchair to enter (minimum width: 0.80m), with a 
              free "circle" of 1.50m diameter at either side of the main door. | 
             
              
             | 
           
           
            | 6 | The door opens automatically 
              or has a door knob easy to manipulate, or the door is not automatic 
              but it is not heavy to push or pull. | 
             
              
             | 
           
           
            | 7 | The emergency door 
              is very accessible from the entire building. The doorway, the door, 
              the floor and the exit are very accessible for a wheelchair user. 
              The way to the emergency door is also clearly indicated inside the 
              building. | 
             
              
             | 
           
         
          
       | 
    
     
      |   | 
        | 
      2 | ALARMS | 
        | 
    
     
      |   | 
        | 
       
        
           
            | 8 | The height of the 
              alarm controls is between 1.00m and 1.40m. | 
             
              
             | 
           
           
            | 9 | The alarms and 
              warnings have audible and clearly visible signals as well as flashing 
              lights.  | 
             
              
             | 
           
         
           
       | 
    
     
      |   | 
        | 
      3 | FIRE EXTINGUISHERS | 
        | 
    
     
      |   | 
        | 
       
        
           
            | 10 | Fire extinguishers 
              are accessible for an ambulant disabled as well as for a wheelchair 
              user, as they are placed at a height of between 0.60m and 1.40m. | 
             
              
             | 
           
         
          
       | 
    
     
      |   | 
        | 
      4 | PUBLIC TELEPHONES | 
        | 
    
     
      |   | 
        | 
       
        
           
            | 11 | There is at least 
              one adapted public telephone in an accessible area of the building. | 
             
              
             | 
           
           
            | 12 | The telephone 
              is between 1.00m and 1.40m high and it has a free space of 0.70m 
              below for the wheelchair to approach.  | 
             
              
             | 
           
         
           
       | 
    
     
      |   | 
        | 
      5 | SIGNS AND SIGNALS | 
        | 
    
     
      |   | 
        | 
       
        
           
            | 13 | Directions and 
              warnings are clear, easy to read and visible. They are placed at 
              a height of 1.00m and 1.70m.  | 
             
              
             | 
           
           
            | 14 | There are adapted 
              signals for the blind at least outside and inside lift cabins and 
              on the toilet doors. | 
             
              
             | 
           
         
          
       | 
    
     
      |   | 
        | 
      6 | CORRIDORS | 
        | 
    
     
      |   | 
        | 
       
        
           
            | 15 | Corridors have 
              a minimum width of 1.50m. | 
             
              
             | 
           
           
            | 16 | They are free 
              of obstacles and the floor is hard, level and non-skid. | 
             
              
             | 
           
         
          
       | 
    
     
      |   | 
        | 
      7 | LIFTS | 
        | 
    
     
      |   | 
        | 
       
        
           
            | 17 | There is at least 
              one lift that gives access to the entire building. | 
             
              
             | 
           
           
            | 18 | The gap between 
              the floor and the lift cabin is no more than 0.01m wide. | 
             
              
             | 
           
           
            | 19 | There is a free 
              doorway at least 0.80m wide. | 
             
              
             | 
           
           
            | 20 | The interior minimum 
              dimensions of the lift are 1.40m x 1.10m. | 
             
              
             | 
           
           
            | 21 | Controls are between 
              1.00m and 1.40m from the floor. | 
             
              
             | 
           
           
            | 22 | There are grab 
              bars at 0.90m/0.95m from the floor on both sides of the cabin. | 
             
              
             | 
           
         
          
       | 
    
     
      |   | 
        | 
      8 | STAIRS | 
        | 
    
     
      |   | 
        | 
       
        
           
            | 23 | There are double 
              handrails on both sides.  | 
             
              
             | 
           
           
            | 24 | The handrails 
              are placed between 0.90m/0.95m from the floor. The handrails are 
              firmly attached so that they do not move or look insecure. | 
             
              
             | 
           
           
            | 25 | The handrails 
              are round or oval and separated at least 0.04m from the wall or 
              other elements. | 
             
              
             | 
           
           
            | 26 | The surface of 
              the steps is hard, level and non-skid. | 
             
              
             | 
           
           
            | 27 | There are no protruding 
              nosing steps. | 
             
              
             | 
           
           
            | 28 | There are no open 
              steps. | 
             
              
             | 
           
           
            | 29 | The maximum height 
              of every step is 0.16m and the minimum length of every step is 0.30m. | 
             
              
             | 
           
         
          
       | 
    
     
      |   | 
        | 
      9 | TOILETS | 
        | 
    
     
      |   | 
        | 
       
        
           
            | 30 | The door of the 
              toilet opens outwards. | 
             
              
             | 
           
           
            | 31 | There is a free 
              circular space of 1.50m diameter in the interior. | 
             
              
             | 
           
           
            | 32 | There are adjustable 
              grab bars at both sides of WC. | 
             
              
             | 
           
           
            | 33 | The WC seat is 
              adjustable or has a seat extender. | 
             
              
             | 
           
           
            | 34 | The bottom of 
              the mirror is no higher than 0.90m. | 
             
              
             | 
           
           
            | 35 | The lower part 
              of the basin is free of obstacles and placed no less than 0.70m 
              from the floor. | 
             
              
             | 
           
           
            | 36 | All elements, 
              controls and mechanisms are placed between 1.60 m and 1.40m from 
              the floor.  | 
             
              
             | 
           
         
          
       | 
    
     
      |   | 
        | 
      10 | ACCESSIBILITY TO THE 
        ENTIRE BUILDING | 
        | 
    
     
      |   | 
        | 
       
        
           
            | 37 | It is possible 
              to access the entire building without need of asking for help. | 
             
              
             | 
           
           
            | 38 | There are no isolated 
              steps or other elements that may obstacle the passage of a wheelchair 
              or a blind person. | 
             
              
             | 
           
           
            | 39 | The building is 
              well illuminated. | 
             
              
             | 
           
           
            | 40 | There are adapted 
              toilets on every floor of the building and they are always unlocked. | 
             
              
             | 
           
         
         
        
          
       | 
    
     
      |   | 
        | 
       
        
           
            | Between 90 
              and 120: ACCESSIBLE  | 
            . | 
           
           
            | Between 60 
              and 89: ACCESSIBLE WITH DIFFICULTY 
             | 
            . | 
           
           
            | Less than 59: 
              NOT ACCESSIBLE  | 
            . | 
           
         
       | 
    
     
      |   | 
        | 
        | 
        | 
    
     
      |   | 
        | 
      
        
       |