Go to the Site Map
Section 1 | BarriersSection 2 | The Sensory DisabledSection 3 | The Manipulatory DisabledSection 4 | The Locomotor DisabledFinal Task 1 | Survey of Accessibility to your SchoolFinal Task 2 | Survey of Accessibility to Public BuildingsFinal Task 3 | Survey of Accessibility to Public Spaces
Section 1 | BarriersSection 2 | The Sensory DisabledSection 3 | The Manipulatory DisabledSection 4 | The Locomotor DisabledAppendix A | Symbols Appendix B | Area of ReachAppendix C | Accessible Areas and Elements from A to ZAppendix D | Glossary Go to Student's Book Site Map Go to  Film Viewing Go to Webquests Go to Written Exercises Go to Student's Worksheets Go to Student's Worksheets Go to Written Exercises Go to Webquests Go to  Film Viewing
   
Go to Site Map

Go to the back pageGo to the top

 
 

CHART 1 | SURVEY OF ACCESSIBILITY TO PUBLIC BUILDINGS

   
Click here and go to the Print Version
     
 
REFERENCE I agree: 3 points
I partially agree: 2 points
I disagree: 1 point
     
  1| MAIN ENTRANCE AND EMERGENCY DOORS  
   
1 | The entrance is level or ramped, with no steps at the threshold.
2 | A ramp is not necessary to access this building, or there is one, which is correct, with handrails at both sides and no more than 12% of gradient.
3 | The only main entrance has no turnstiles or revolving doors.
4 | The floor outside and inside the main door is hard, level and non-skid. It is dry and clean.
5 | The doorway is wide enough for a wheelchair to enter (minimum width: 0.80m), with a free "circle" of 1.50m diameter at either side of the main door.
6 | The door opens automatically or has a door knob easy to manipulate, or the door is not automatic but it is not heavy to push or pull.
7 | The emergency door is very accessible from the entire building. The doorway, the door, the floor and the exit are very accessible for a wheelchair user. The way to the emergency door is also clearly indicated inside the building.

  2 | ALARMS  
   
8 | The height of the alarm controls is between 1.00m and 1.40m.
9 | The alarms and warnings have audible and clearly visible signals as well as flashing lights.

 

  3 | FIRE EXTINGUISHERS  
   
10 | Fire extinguishers are accessible for an ambulant disabled as well as for a wheelchair user, as they are placed at a height of between 0.60m and 1.40m.

 

  4 | PUBLIC TELEPHONES  
   
11 | There is at least one adapted public telephone in an accessible area of the building.
12 | The telephone is between 1.00m and 1.40m high and it has a free space of 0.70m below for the wheelchair to approach.

 

  5 | SIGNS AND SIGNALS  
   
13 | Directions and warnings are clear, easy to read and visible. They are placed at a height of 1.00m and 1.70m.
14 | There are adapted signals for the blind at least outside and inside lift cabins and on the toilet doors.

 

  6 | CORRIDORS  
   
15 | Corridors have a minimum width of 1.50m.
16 | They are free of obstacles and the floor is hard, level and non-skid.

 

  7 | LIFTS  
   
17 | There is at least one lift that gives access to the entire building.
18 | The gap between the floor and the lift cabin is no more than 0.01m wide.
19 | There is a free doorway at least 0.80m wide.
20 | The interior minimum dimensions of the lift are 1.40m x 1.10m.
21 | Controls are between 1.00m and 1.40m from the floor.
22 | There are grab bars at 0.90m/0.95m from the floor on both sides of the cabin.

 

  8 | STAIRS  
   
23 | There are double handrails on both sides.
24 | The handrails are placed between 0.90m/0.95m from the floor. The handrails are firmly attached so that they do not move or look insecure.
25 | The handrails are round or oval and separated at least 0.04m from the wall or other elements.
26 | The surface of the steps is hard, level and non-skid.
27 | There are no protruding nosing steps.
28 | There are no open steps.
29 | The maximum height of every step is 0.16m and the minimum length of every step is 0.30m.

 

  9 | TOILETS  
   
30 | The door of the toilet opens outwards.
31 | There is a free circular space of 1.50m diameter in the interior.
32 | There are adjustable grab bars at both sides of WC.
33 | The WC seat is adjustable or has a seat extender.
34 | The bottom of the mirror is no higher than 0.90m.
35 | The lower part of the basin is free of obstacles and placed no less than 0.70m from the floor.
36 | All elements, controls and mechanisms are placed between 1.60 m and 1.40m from the floor.

 

  10 | ACCESSIBILITY TO THE ENTIRE BUILDING  
   
37 | It is possible to access the entire building without need of asking for help.
38 | There are no isolated steps or other elements that may obstacle the passage of a wheelchair or a blind person.
39 | The building is well illuminated.
40 | There are adapted toilets on every floor of the building and they are always unlocked.

TOTAL SCORE
 

 

   
Between 90 and 120: ACCESSIBLE  
Between 60 and 89: ACCESSIBLE WITH DIFFICULTY  
Less than 59: NOT ACCESSIBLE  
       
       
Go to Site Map

Go to the back pageGo to the top