CHART 1 | SURVEY OF ACCESSIBILITY TO PUBLIC BUILDINGS
|
|
|
|
![Click here and go to the Print Version](imagenes/pix_pv.gif) |
|
|
|
![](imagenes/pix_blanc.gif) |
|
REFERENCE |
I agree: 3
points |
I partially agree: 2
points |
I disagree: 1
point |
|
|
|
|
![](imagenes/pix_blanc.gif) |
|
![](imagenes/05env_pix.gif) |
1| MAIN ENTRANCE AND EMERGENCY
DOORS |
|
|
|
1 | The entrance
is level or ramped, with no steps at the threshold. |
![](imagenes/05env_cuad.gif) |
2 | A ramp is not
necessary to access this building, or there is one, which is
correct, with handrails at both sides and no more than 12% of
gradient. |
![](imagenes/05env_cuad.gif) |
3 | The only main
entrance has no turnstiles or revolving doors. |
![](imagenes/05env_cuad.gif) |
4 | The floor outside
and inside the main door is hard, level and non-skid. It is
dry and clean. |
![](imagenes/05env_cuad.gif) |
5 | The doorway
is wide enough for a wheelchair to enter (minimum width: 0.80m),
with a free "circle" of 1.50m diameter at either side of the
main door. |
![](imagenes/05env_cuad.gif) |
6 | The door opens
automatically or has a door knob easy to manipulate, or the
door is not automatic but it is not heavy to push or pull. |
![](imagenes/05env_cuad.gif) |
7 | The emergency
door is very accessible from the entire building. The doorway,
the door, the floor and the exit are very accessible for a wheelchair
user. The way to the emergency door is also clearly indicated
inside the building. |
![](imagenes/05env_cuad.gif) |
|
|
![](imagenes/05env_pix.gif) |
2 | ALARMS |
|
|
|
8 | The height
of the alarm controls is between 1.00m and 1.40m. |
![](imagenes/05env_cuad.gif) |
9 | The alarms
and warnings have audible and clearly visible signals as well
as flashing lights. |
![](imagenes/05env_cuad.gif) |
|
|
![](imagenes/05env_pix.gif) |
3 | FIRE EXTINGUISHERS |
|
|
|
10 | Fire extinguishers
are accessible for an ambulant disabled as well as for a wheelchair
user, as they are placed at a height of between 0.60m and 1.40m. |
![](imagenes/05env_cuad.gif) |
|
|
![](imagenes/05env_pix.gif) |
4 | PUBLIC TELEPHONES |
|
|
|
11 | There is at
least one adapted public telephone in an accessible area of
the building. |
![](imagenes/05env_cuad.gif) |
12 | The telephone
is between 1.00m and 1.40m high and it has a free space of 0.70m
below for the wheelchair to approach. |
![](imagenes/05env_cuad.gif) |
|
|
![](imagenes/05env_pix.gif) |
5 | SIGNS AND SIGNALS |
|
|
|
13 | Directions
and warnings are clear, easy to read and visible. They are placed
at a height of 1.00m and 1.70m. |
![](imagenes/05env_cuad.gif) |
14 | There are
adapted signals for the blind at least outside and inside lift
cabins and on the toilet doors. |
![](imagenes/05env_cuad.gif) |
|
|
![](imagenes/05env_pix.gif) |
6 | CORRIDORS |
|
|
|
15 | Corridors
have a minimum width of 1.50m. |
![](imagenes/05env_cuad.gif) |
16 | They are free
of obstacles and the floor is hard, level and non-skid. |
![](imagenes/05env_cuad.gif) |
|
|
![](imagenes/05env_pix.gif) |
7 | LIFTS |
|
|
|
17 | There is at
least one lift that gives access to the entire building. |
![](imagenes/05env_cuad.gif) |
18 | The gap between
the floor and the lift cabin is no more than 0.01m wide. |
![](imagenes/05env_cuad.gif) |
19 | There is a
free doorway at least 0.80m wide. |
![](imagenes/05env_cuad.gif) |
20 | The interior
minimum dimensions of the lift are 1.40m x 1.10m. |
![](imagenes/05env_cuad.gif) |
21 | Controls are
between 1.00m and 1.40m from the floor. |
![](imagenes/05env_cuad.gif) |
22 | There are
grab bars at 0.90m/0.95m from the floor on both sides of the
cabin. |
![](imagenes/05env_cuad.gif) |
|
|
![](imagenes/05env_pix.gif) |
8 | STAIRS |
|
|
|
23 | There are
double handrails on both sides. |
![](imagenes/05env_cuad.gif) |
24 | The handrails
are placed between 0.90m/0.95m from the floor. The handrails
are firmly attached so that they do not move or look insecure. |
![](imagenes/05env_cuad.gif) |
25 | The handrails
are round or oval and separated at least 0.04m from the wall
or other elements. |
![](imagenes/05env_cuad.gif) |
26 | The surface
of the steps is hard, level and non-skid. |
![](imagenes/05env_cuad.gif) |
27 | There are
no protruding nosing steps. |
![](imagenes/05env_cuad.gif) |
28 | There are
no open steps. |
![](imagenes/05env_cuad.gif) |
29 | The maximum
height of every step is 0.16m and the minimum length of every
step is 0.30m. |
![](imagenes/05env_cuad.gif) |
|
|
![](imagenes/05env_pix.gif) |
9 | TOILETS |
|
|
|
30 | The door of
the toilet opens outwards. |
![](imagenes/05env_cuad.gif) |
31 | There is a
free circular space of 1.50m diameter in the interior. |
![](imagenes/05env_cuad.gif) |
32 | There are
adjustable grab bars at both sides of WC. |
![](imagenes/05env_cuad.gif) |
33 | The WC seat
is adjustable or has a seat extender. |
![](imagenes/05env_cuad.gif) |
34 | The bottom
of the mirror is no higher than 0.90m. |
![](imagenes/05env_cuad.gif) |
35 | The lower
part of the basin is free of obstacles and placed no less than
0.70m from the floor. |
![](imagenes/05env_cuad.gif) |
36 | All elements,
controls and mechanisms are placed between 1.60 m and 1.40m
from the floor. |
![](imagenes/05env_cuad.gif) |
|
|
![](imagenes/05env_pix.gif) |
10 | ACCESSIBILITY TO
THE ENTIRE BUILDING |
|
|
|
37 | It is possible
to access the entire building without need of asking for help. |
![](imagenes/05env_cuad.gif) |
38 | There are
no isolated steps or other elements that may obstacle the passage
of a wheelchair or a blind person. |
![](imagenes/05env_cuad.gif) |
39 | The building
is well illuminated. |
![](imagenes/05env_cuad.gif) |
40 | There are
adapted toilets on every floor of the building and they are
always unlocked. |
![](imagenes/05env_cuad.gif) |
|
|
|
Between 90
and 120: ACCESSIBLE |
|
Between 60
and 89: ACCESSIBLE WITH DIFFICULTY
|
|
Less than 59:
NOT ACCESSIBLE |
|
|
|
|
|
|
|
|
|
|